A–5  SWS Maximum CAZ Depressuriza­tion

Appliance Type

 Max. Depress.

Atmospheric water heater only (Category I, natural draft), open-combustion appliances, and orphaned water heaters

 2 pa

Atmospheric water heater (Category I, natural draft) and atmospheric furnace (Category I, natural draft), common-vented, open-combustion appliances

 3 pa

Gas furnace or boiler, Category I or Category I fan-assisted, open-combustion appliances, and stand-alone gas water heaters

 5 pa

Oil or gas unit with power burner, low- or high-static pressure burner, open combustion appliances

 5 pa

Wood-burning appliances

7 pa

Open-combustion furnaces or boilers with fan-pow­ered horizontal venting

15 pa

Pellet stove with draft fan and sealed vent

15 pa

Direct-vent, sealed combustion appliances with forced draft

25 pa