8.22   SWS Alignment

Field Guild Topic

SWS Detail

Combustion-Safety Evaluation

2.0105.1 Combustion Worker Safety

Combustion-Safety Observations

 

Leak-Testing Gas Piping

 

Carbon Monoxide (CO) Testing

2.0105.1 Combustion Worker Safety,
2.0301.2 Carbon Monoxide Alarm or Monitor

Worst-Case CAZ Depressurization Testing

2.0105.1 Combustion Worker Safety,
2.0201.1 Combustion Appliance Zone (CAZ) Testing,
2.0201.2 Combustion Safety

Mitigating CAZ Depressurization and Spillage

 

Zone Isolation for Atmospherically Vented Appliances

 

Electronic Combustion Analysis

5.3003.2 Combustion Analysis of Oil-Fired Appliances

Critical Combustion-Testing Parameters

 

Heating System Replacement

 

Combustion Furnace Replacement

5.3001.1 Load Calculation and Equipment Selection,
5.3001.2 Ductwork and Termination Design,
5.3002.1 Preparation for New Equipment,
5.3003.1 Data Plate Verification

Gas-Fired Heating Installation

2.0201.2 Combustion Safety

Combustion Boiler Replacement

2.0105.1 Combustion Worker Safety,
5.3001.1 Load Calculation and Equipment Selection,
5.3101.2 Space Load Calculation—Heat Emitter Sizing

Oil-Fired Heating Installation

2.0201.2 Combustion Safety, 2.0203.3 Draft Regulation—Category I Appliance,
5.3003.9 Heating and Cooling Controls,
5.3003.4 Evaluating Electrical Service

Evaluating Oil Tanks

 

Combustion Space Heater Replacement

2.0201.2 Combustion Safety

Space Heater Operation

 

Unvented Space Heaters

2.0202.1 Unvented Space Heaters: Propane, Natural Gas, and Kerosene Heaters,
2.0401.1 Air Sealing Moisture Precautions

Gas Burner Safety & Efficiency Service

 

Combustion Efficiency Test for Furnaces

 

Inspecting Gas Combustion Equipment

 

Testing and Adjustment

 

Oil Burner Safety and Efficiency Service

 

Oil Burner Testing and Adjustment

5.3003.2 Combustion Analysis of Oil-Fired Appliances

Oil Burner Inspection and Maintenance

5.3003.4 Evaluating Electrical Service

Inspecting Furnace Heat Exchangers

 

Wood Stoves

 

Wood Stove Clearances

 

Stove Clearances

 

Wood Stove Inspection

 

Inspecting Venting Systems

 

Vent Connectors

 

Masonry Chimneys

2.0203.2 Combustion Flue Gas—Orphaned Water Heaters

Manufactured Chimneys

 

Chimney Terminations

 

Air Leakage through Masonry Chimneys

4.1001.3 Fireplace Chimney and Combustion Flue Vents

Special Venting Considerations for Gas

 

Venting Fan-Assisted Furnaces and Boilers

 

Combustion Air

2.0203.1 Combustion Air for Natural Draft Appliances

Un-Confined-Space Combustion Air

 

Confined-Space Combustion Air

 

Ducted Air Distribution

 

Sequence of Operations

 

Solving Airflow Problems

5.3003.3 Evaluating Air Flow

Unbalanced Supply-Return Airflow Test

 

Evaluating Furnace Performance

 

Improving Forced-Air System Airflow

 

Evaluating Duct Air Leakage

 

Troubleshooting Duct Leakage

 

Measuring Duct Air Leakage with a Duct Blower

 

Measuring House Pressure Caused by Duct Leakage

 

Sealing Duct Leaks

 

Sealing Return Ducts

3.1602.1 Air Sealing Duct System,
3.1602.5 Return—Framed Platform,

3.1602.4 Air Sealing System Components,
3.1602.7 Return and Supply Plenums in Basements and Crawl Spaces

Sealing Supply Ducts

 3.1602.1 Air Sealing Duct System,
3.1602.5 Return—Framed Platform
3.1602.4 Air Sealing System Components,
3.1602.7 Return and Supply Plenums in Basements and Crawl Spaces

Materials for Duct Sealing

 

Duct Insulation

4.1601.1 Insulating Flex Ducts, 4.1601.2 Insulating Metal Ducts

Hot-Water Space-Heating Distribution

 

Boiler Efficiency and Maintenance

 

Distribution System Improvements

 

Steam Heating and Distribution

 

Steam System Maintenance

 

Steam System Energy Conservation

 

Programmable Thermostats

 

Electric Heat

 

Electric Baseboard Heat

 

Electric Furnaces

 

Central Heat-Pump Energy Efficiency

 

Room Heat Pumps

 

Ductless Minisplit Pumps

 

Evaluating Ducted Central Air-Conditioning Systems

 

Central Air-Conditioner Inspection

 

Air-Conditioner Sizing

 

Duct Leakage and System Airflow

 

Evaluating Air-Conditioner Charge